4 - The PatchMix DSP Mixer
Mixer Strip Creation
40 Creative Professional
To Add an ASIO Direct Monitor Send/Return:
1. Right-Click over the Insert section. A pop-up dialog box appears.
2. Select Insert ASIO Direct Monitor from the list of options. The following dialog
box appears.
3. Choose one of the Send Outputs. Click on a destination to select it.
4. Choose one of the Return Inputs. Click on a source to select it.
5. Click OK to select the Send and Return, or Cancel to cancel the operation.
Meter Inserts
Keeping track of signal levels is important in any audio system, be it analog or digital.
You want to keep the signal levels running as close to maximum in order to achieve
high resolution and low noise. On the other hand, you don’t want the signal level so
high as to cause clipping. To help you maintain optimum signal levels, we have
included Peak Level Meters, which can be dropped into any insert location.
The insert meters are of the “peak hold” type. The topmost bar in the meter holds its
highest level for a second to let you see transients that would otherwise be too quick for
the eye.
The peak meters are also color-coded to indicate the signal strength. The chart below
outlines the meanings of the colors. Avoid lighting the topmost red bar, as this
indicates distortion of the signal. Click on the clip indicator to turn it off.
One of the most obvious uses of the insert meters is to set input levels. On the analog
inputs, the analog-to-digital converter (ADC) is one of the most critical points in the
signal path. You want the input signal level to drive the 24-bit ADCs into their
optimum range without clipping. A reading of 0dB on an input meter indicates signal
clipping.
Meter Color Indicates
Red Indicates signal clipping.
Yellow Good strong signal level.
Green Signal is present.
--12dB
Level
10203040506070
Each bar of the meter equals 1dB. The yellow bars begin at -12dB below full scale.
Page view 39