3BUS 208 000 R130188 Platform Tuning
Head Position Setup
This section defines specific head position locations. See Figure 5-12. The position
variables are listed below.
Garage Position (OFF)
The Garage Position is the position on the Scanning Platform, next to the process,
where maintenance is performed. The entered distance should be the smallest of
the Host positions, as measured from the home end column.
If personal safety and service access needs dictate, it is possible to place the off
sheet position adjacent to the far column end of the platform. In this case, leave the
standardize position at the home end if possible and note that when going on-sheet,
the heads will traverse the entire platform length from the far end to the home end
in order to start its scan.
Standardize Position (STDZ)
The Standardize Position is the position where sensor standardization occurs. This
position typically is the same as the off sheet position and should never be close
enough to the sheet edge so that the far edge detector sees the sheet edge. The
entered distance should be less than the value for the Minimum Home EOS Position.
Normally the off-sheet and standardize positions are identical because this allows
the automatic check sample sequence to be extended after standardize without
moving the head to a new position and enhances accuracy.
Minimum Home Measure Position (LHEOS)
This position defines the home position of the maximum scan width, and the
minimum limit for the Current Home Scan Limit. The Scanning Platform will never
scan outside of the minimum measure position. This value should be greater than
those for the Garage Position and the Standardize Position. This position is called
the Home Measure Limit.
Current Home Scan Position (KHEOS)
This position is the current home side scan limit for the present sheet width. This
value will never be less than the Minimum Home Measure Position. This position
is called the Home Scan Limit.
Default Single Point Position (SPPOS)
This is the default single-point measurement position, when the Scanning Platform
is placed in the single-point mode. The entered value must be between the Current
Home Scan Position and Current Far Scan Position.