3BUS 208 000 R1301122 Measurement Setup
Enter Calibration Head Constants
Calibration head constants have to be entered into the Scanning Platform software.
The values for these constants can be found on reports for the Basis Weight (includes
Air Column), and Ash sensors or tags for the IR Moisture and Caliper sensors. For
the OptiPak and Gloss sensor, values are entered through an interactive genrpt
program that allows the software to calibrate the constants it needs on line.
Basis Weight Sensor
The Basis Weight sensor head constants are K0, K1, K2, K3, WCC, and AM. These
constants may be different for every sensor. They may need to be changed if certain
components in the sensor geometry are repaired or replaced. Change sensor
constants using the Basis Weight Health Report, Figure 6-5. See Operation of NT
Workstation Health Reports” on page 112 for an overview of the Health Reports.
The Basis Weight sensor calibration constants consist of one or two sets of constants.
Table 6-15 lists the head constants for the Basis Weight sensor. Table 6-16 lists the
optional constants and values for the Air Temperature Compensation (ATC).
Table 6-15 Basis Weight Calibration Constants
Head Constant
Value - betaSensor01
(Enter values from the Calibration Report)
K0
K1
K2
K3
WCC
(Smart Basis
Weight only)
AM
(Smart Basis
Weight only)