PROPRIETARY DATA: This document contains proprietary data of ABB Inc. No disclosure, distribution (electronic or otherwise),
or other means of dissemination may be made without written permission.
3BUS 208 000 R1301202 Replacement Procedures
Flex Cable Suspension
Complete the following steps to replace the cable suspension. Refer to
Figure 10-10 and Figure 10-11.
Exercise care when working with toothed belt and
toothed gear equipment. Do not wear ties or loose
clothing while working near equipment.
The Scanning Platform design allows replacement of this
item while the customer’s process is running. Exercise
caution to ensure that the flex cable is kept clear of the
process while being removed and replaced.
1. Put the platform in local mode and jog the head to the idler end column.
2. Pull out the carriage PC board, and disconnect the signal and power cable
connectors. At the carriage end only, cut off the connectors from the signal and
power cables.
Figure 10-10 Carriage Assembly (Top View)
Signal Cable
Connecter
Upper Assembly Top View
Cable
Carrier
Ribbon
Cable
Electric
Chassis
J1 J2
J12
J21
12 Volt
Power Supply
Electrometer
Assembly
Aux Power Cable
Connecter
High Voltage
Power Supply
Auxiliary
Cable Line
Aux Signal
Cable Connector
Power Cable
Connectors
Sensor Cable
Connector